4. SERVO FUNCTION DETAILS B-65150E/04
− 202 −
If this function is used with other system software, a separate detector
disconnection alarm and an "abnormal-load detection alarm" occur
simultaneously. (For the Series 15-B, this phenomenon occurs in all
editions.)
(4) Setting parameters
#7 #6 #5 #4 #3 #2 #1 #0
1745
−
HD2O HDIS
2205
−
HDIS (#4) Specifies whether to enable separate detector hardware disconnection
stop distance reduction function as follows:
1: To enable
0: To disable
HD2O (#5) Specifies whether to apply the separate detector hardware
disconnection stop distance reduction function to axes subjected to
synchronization control, as follows:
1: To apply
0: Not to apply
NOTE 1
When applying this function to axes under
synchronization control (including simplified
synchronization), follow the steps below:
1 Change the servo axis setting (No. 1023) for two axes
subjected to simplified synchronization so that the two
axes can be controlled on 1DSP.
2 Set HD2O (bit 5) to 1 for both axes under
synchronization control.