4. SERVO FUNCTION DETAILS B-65150E/04
− 184 −
Example of parameter setting)
Position gain (1/s)
Usually set
value
Newly set
value
15
1500 1523
16.66
1666 1694
20
2000 2041
25
2500 2564
30
3000 3093
33.33
3333 3448
35
2500 3627
40
4000 4167
45
4500 4712
50
5000 5263
B. Method for internally changing the servo axis position
gain
An additional function is available, which enables internal
automatic modification of only the servo axis position gain
for synchronization.
(Series and editions of applicable servo software)
Series 9080/N(15) and subsequent editions (Series 15-B,
16-C, 18-C)
Series 90A0/A(01) and subsequent editions (Series 15i, 16i,
18i)
(Parameter)
#7 #6 #5 #4 #3 #2 #1 #0
1749
−
FADPGC
2209
−
FADPGC (#3) Specifies whether to perform synchronization in rigid tapping mode
when FAD is set up, as follows:
1: To perform ← To be set
0: Not to perform
NOTE
1 If this parameter is set, the servo position gain
increases by 1 ms even when rigid tapping is not
used.
2 It is necessary to set this parameter for all axes that
are subjected to contouring.
NOTE
After setting this bit, switch the power off and on
again.