B-65150E/04 4. SERVO FUNCTION DETAILS
− 119 −
(6) Series and editions of applicable servo software
Function for disabling the observer in the stop state
Series 9060/W(23) and subsequent editions (Series 15-B, 16-A,
18-A, 20, 21, Power Mate)
Series 9066/B(02) and subsequent editions (Series 20, 21, Power
Mate)
Series 9070/H(08) and subsequent editions (Series 15-B, 16-B,
18-B)
Series 9080/A(01) and subsequent editions (Series 15-B, 16-C,
18-C)
Series 9081/C(03) and subsequent editions (Series 15-B, 16-C,
18-C)
Series 9090/C(03) and subsequent editions (Series 16i, 18i, 21i,
Power Mate i)
Series 90A0/A(01) and subsequent editions (Series 15i, 16i, 18i,
21i, Power Mate i)
(7) Setting parameters
<1> Function bit
#7 #6 #5 #4 #3 #2 #1 #0
1960
−
MOVO
2018
−
MOVO (#1) The function for disabling the observer in the stop state is:
0: Disabled
1: Enabled ← Set this value.
<2> Level at which the observer is determined as being disabled
1730
−
Level at which the observer is determined as being disabled
2119
−
[Increment system] Detection unit
[Typical setting] 1 to 10
If the absolute value of the positional deviation is less than the level at
which the observer is determined as being disabled, the observer
function is disabled.
(Usage)
If, when the observer function is enabled, the machine is unstable
in the machine stop state, set the function bit and the level at
which the observer is determined as being disabled so that it is
greater than the peak absolute value of the oscillating positional
deviation.
NOTE
This parameter is also used for the stop determination
level of the function for changing the proportional gain
in the stop state.