B-65150E/04 5. DETAILS OF PARAMETERS
− 295 −
DBST (#1) The emergency stop distance reduction
function type 1 is:
0: Not used
1: Used
⇒ See Subsec. 4.11.1.
Related parameters:
8X05 (Series 0-C), 1883
(Series 15-A), 8X83 (Series 0-
C), and 1976 (Series 15-A)
PKVE (#2) The velocity dependent current loop
gain variable function is:
0: Not used
1: Used
Related parameters:
8X74 (Series 0-C) and 1967
(Series 15-A)
ACCF (#4) Specifies the amount of velocity
feedback data to be used as follows:
0: Velocity feedback for the latest 2
ms
1: Velocity feedback for the latest 1
ms
Related parameters:
8X67 (Series 0-C), 1895
(Series 15-A), 8X76 (Series 0-
C), and 1969 (Series 15-A)
DCBE (#6) During deceleration, back
electromotive force compensation is:
0: Not used
1: Used
#7 #6 #5 #4 #3 #2 #1 #0
8X09 BLST BLCU K2VC ADBL SERD
1953
SERD (#0) The dummy serial feedback function
is:
0: Not used
1: Used
If this parameter is specified for axes
to which a servo amplifier or motor is
not connected, alarms related to pulse
coders and amplifiers are ignored.
⇒ See Subsec. 4.9.1.
ADBL (#2) The new backlash acceleration
function is:
0: Not used
1: Used
Related parameters:
8X48 (Series 0-C), 1860
(Series 15-A), 8X87 (Series 0-
C), and 1980 (Series 15-A)
K2VC (#4) The function for changing the
proportional gain in the stop state is:
0: Not used
1: Used
⇒ See Subsec. 4.4.3.
Related parameters:
8X89 (Series 0-C) and 1982
(Series 15-A)
BLCU (#6) The function for enabling the backlash
acceleration function only during
cutting is :
0: Not used
1: Used
⇒ See Subsecs. 4.6.4 and 4.6.5.
BLST (#7) The backlash acceleration stop
function is :
0: Not used
1: Used
⇒ See Subsec. 4.6.4.
Related parameters:
8X82 (Series 0-C) and 1975
(Series 15-A)