3/3Descri
tion
Desig
DateEd
01 00.01.14
Su
i
ama
Newl
desi
ned
Notice of the update of Digital
Servo Software 9090 series
B-65150E/04-004
FANUC LTD
Attachment 1:
About the change of parameter table.
About the change of parameter table.About the change of parameter table.
About the change of parameter table.
We have changed the standard parameter table about the following motors (Table1).
The purpose of change is to improve the stability at high speed.
α
12/3000,
α
22/3000,
α
30/3000,
α
22/3000HV,
α
12/3000HV,
α
30/3000HV,
α
30/3000HV
Table 1
Motor model
α
12HV
α
12/3
α
22/3
α
30/3
α
22/3HV
α
30/3HV
α
M30HV
Motor specification 0176 0143 0148 0153 0177 0178 0186
Motor type No. 3 19 21 23 102 103 107
Symbol Parameter No.
FS15 FS16,18
EMFCMP 1868 2056 -12840 -12840 -12820 4500 0 0 0
PVPA 1869 2057 -6925 -7690 -8970 -5130 -6412 -3856 -6422
PALPH 1870 2058 -2832 -1500 -1226 -2500 -2240 -3000 -3226
MGSTCM 1703 2110 16 16 24 0 2584 2592 24
MFWKCE 1736 2128 2000 2000 2000 6000 2778 4000 1000
MFWKBL 1752 2129 2581 1551 2571 2581 1554 1287 3221
LP2GP 1753 2130 0 0 0 0 0 0 0
LP4GP 1754 2131 0 0 0 0 0 0 0
LP6GP 1755 2132 0 0 0 0 0 0 0
PHDLY1 1756 2133 0 0 0 5160 0 0 0
PHDLY2 1757 2134 0 0 0 12840 0 0 0
(Bold-bordered parameters are changed part from the previous one.)
And we have corrected the standard parameter table about the following motors (Table2).
α
40/FAN,
α
40/2000: To improve the stability at high-speed rotation.
α
300/2000,
α
400/2000: To correct the wrong value of MAXCRT parameter.
Wrong Value: 135 / Correct Value: 365
Table 2
Motor model
α
40/FAN
α
40/2
α
300/2
α
400/2
Motor specification 0158 0157 0337 0338
Motor type No. 29 30 111 112
Symbol Parameter No.
FS15 FS16,18
EMFCMP 1868 2056 -12820 -12820 0 0
MAXCRT 1788 2057 135 135 365 365
(Bold-bordered parameters are changed part)
Notice:
We’ve already applied these changes of Table2 to the new edition of the Servo Parameter