B-65150E/04 APPENDIX
B. ANALOG SERVO INTERFACE SETTING PROCEDURE
− 351 −
b) Directly enter all parameters listed in the following table. Before
doing this, understand the meaning of each parameter sufficiently.
For detailed descriptions about parameter setting, refer to the
respective CNC Connection Manuals and Parameter Manuals.
Analog and digital servo axes can be used together as shown in the
reference examples below.
Parameter number
Series 15i Power Mate i
Meaning
1023 1023 Servo axis number for each axis
1093 1905 (Bit type parameter)
1080 to 1089 1910 to 1919 Conversion table value for slave number
1094 1936 Connector number for interface unit 1
1095 1937 Connector number for interface unit 2
(Reference)
FSSB setting example where an analog servo interface unit is used
(The parameter numbers on the upper row in the table apply to the
Series 15i, and those on the lower row, to the Power Mate i.)
[Setting example 1: Two analog servo axes]
Let the analog servo interface unit be slave 1. Assume that analog
amplifiers are connected behind the analog servo interface unit,
and let them be slaves 2 and 3 sequentially.
CNC
Analog amplifier 1
FSSB
X-axis
Y-axis
Analog servo
interface unit 1
(Basic unit)
JV12L
Slave 1
Slave 2
Slave 3
No.
1080 1081 1082 1083 1084 1085 1086 1087 1088 1089
No.
1910 1911 1912 1913 1914 1915 1916 1917 1918 1919
Set value
16 0 1 40 40 40 40 40 40 40
Axis
No. 1023 No. 1093 No. 1094 No. 1095
Axis
No. 1023 No. 1905 No. 1936 No. 1937
X
1 01000000 0 0
Y
2 01000000 1 0