4. SERVO FUNCTION DETAILS B-65150E/04
− 178 −
The fine acceleration/deceleration function (linear type) is supported in
the following:
Series 9080/K(11) and subsequent editions (Series 15-B, 16-C,
18-C)
Series 9090/E(05) and subsequent editions (Series 16i, 18i, 21i,
Power Mate i)
Series 90A0/A(01) and subsequent editions (Series 15i, 16i, 18i,
21i, Power Mate i)
(4) Setting basic parameters
#7 #6 #5 #4 #3 #2 #1 #0
1951
−
FAD
2007
−
FAD 1: Enables the fine acceleration/deceleration function.
#7 #6 #5 #4 #3 #2 #1 #0
1749
−
FADL
2209
−
FADL 0: FAD bell-shaped
1: FAD linear type
1702
−
Fine acceleration/deceleration time constant (ms)
2109
−
[Valid data range] 8 to 64 (Standard setting: 40)
A value exceeding the valid data range is clamped to the upper or lower
limit of the range.
When the fine acceleration/deceleration and feed-forward functions are
used together, set the coefficient in the following parameter.
(The parameter No. is the same as that used for advanced preview
control.)
NOTE
With Series 9066, the fine acceleration/deceleration
function, used separately for cutting and rapid
traverse, and the linear fine accelration/deceleration
funcion cannot be used. (Future support of these
functions is not scheduled.)
NOTE
To enable this bit setting, the power must be turned
off then back on.
NOTE
To enable this bit setting, the power must be turned
off then back on.