4. SERVO FUNCTION DETAILS B-65150E/04
− 214 −
4.12.2 Unexpected Disturbance Detection Performed Separately for
Cutting and Rapid Traverse
(1) Overview
An improvement has been made so that the alarm threshold for
unexpected disturbance detection can be set separately for rapid
traverse and cutting.
(2) Series and editions of applicable servo software
Series 9066/H(08) and subsequent editions (Series 20, 21, Power Mate)
Series 9080/J(10) and subsequent editions (Series 15-B, 16-C, 18-C)
Series 9090/A(01) and subsequent editions (Series 16i, 18i, 21i, Power
Mate i)
Series 90A0/A(01) and subsequent editions (Series 15i, 16i, 18i, 21i,
Power Mate i)
(3) Setting parameters
A threshold can be set separately for cutting and rapid traverse by
setting the following bit when the unexpected disturbance detection
function is used:
#7 #6 #5 #4 #3 #2 #1 #0
1740
−
ABG0
2200
−
Alarm thresholds for unexpected disturbance detection are set in the
following parameters:
1997
−
2104
−
Unexpected disturbance detection threshold for cutting
(same as the conventional setting)
[Valid data range] 0 to 7282
1765
−
Unexpected disturbance detection threshold for rapid traverse
2142
−
[Valid data range] 0 to 7282