2. SETTING α SERIES SERVO PARAMETERS B-65150E/04
− 30 −
(For the Series 15-B)
Check the value in No. 1023 for the axis where a parameter error
occurred. According to the value, set a parameter as follows:
Axis for which an odd value is set in parameter No. 1023:
No. 1726 = 20480
Axis for which an even value is set in parameter No. 1023:
No. 1726 = 22528
Then, open the contents-of-memory screen, and check the data at the
address shown below. Check the 4-digit hexadecimal value.
[When the system is not a multiaxis system]
Axis for which 1 is set in No. 1023: > 908001C0
Axis for which 2 is set in No. 1023: > 908001C2
Axis for which 3 is set in No. 1023: > 90A001C0
Axis for which 4 is set in No. 1023: > 90A001C2
Axis for which 5 is set in No. 1023: > 43C801C0
Axis for which 6 is set in No. 1023: > 43C801C2
Axis for which 7 is set in No. 1023: > 43CA01C0
Axis for which 8 is set in No. 1023: > 43CA01C2
[When the system is a multiaxis system]
Axis for which 1 is set in No. 1023: > A9C801C0
Axis for which 2 is set in No. 1023: > A9C801C2
Axis for which 3 is set in No. 1023: > A9CA01C0
Axis for which 4 is set in No. 1023: > A9CA01C2
Axis for which 5 is set in No. 1023: > AAC801C0
Axis for which 6 is set in No. 1023: > AAC801C2
Axis for which 7 is set in No. 1023: > AACA01C0
Axis for which 8 is set in No. 1023: > AACA01C2
Axis for which 9 is set in No. 1023: > ABC801C0
Axis for which 10 is set in No. 1023: > ABC801C2
Axis for which 11 is set in No. 1023: > ABCA01C0
Axis for which 12 is set in No. 1023: > ABCA01C2
Axis for which 13 is set in No. 1023: > ACC801C0
Axis for which 14 is set in No. 1023: > ACC801C2
Axis for which 15 is set in No. 1023: > ACCA01C0
Axis for which 16 is set in No. 1023: > ACCA01C2
(For the Series 16-C and 18-C)
Set parameters according to the following table:
Setting in No. 1023 1st
axis
2nd
axis
3rd
axis
4th
axis
5th
axis
6th
axis
7th
axis
8th
axis
No. 8950#0 1 1 1 1 1 1 1 1
No. 8960 1304 1304 1312 1312 1800 1800 1808 1808
No. 2115 20480 22528 20480 22528 20480 22528 20480 22528
NOTE
To display these addresses, search for the following
address. (Otherwise, a system alarm is issued.)
For 9-inch CRT display: Address xxxxx180
For 15-inch CRT display: Address xxxxx100