5. DETAILS OF PARAMETERS B-65150E/04
− 302 −
#7 #6 #5 #4 #3 #2 #1 #0
1883
−
SFCM BRKC FEED
2005 1005
FEED (#1) The feed forward function is:
0: Not used
1: Used
⇒ See Subsecs. 4.6.1, 4.6.2, and
4.6.3.
Related parameters:
1961 (Series 15), 2068 (Series
16), 1068 (Power Mate-E),
1985 (Series 15), and 2092
(Series 16)
BRKC (#6) The vertical-axis brake control
function is:
0: Not used
1: Used
⇒ See Sec. 4.10.
Related parameters:
1976 (Series 15), 2083 (Series
16), and 1083 (Power Mate-E)
SFCM (#7) The static friction compensation
function is:
0: Not used
1: Used
⇒ See Subsec. 4.6.6.
Related parameters:
1808 (Series 15), 2003 (Series
16), 1003 (Power Mate-E),
1965 (Series 15), 2072 (Series
16), 1072 (Power Mate-E),
1966 (Series 15), 2073 (Series
16), and 1073 (Power Mate-E)
#7 #6 #5 #4 #3 #2 #1 #0
1884
−
DCBE ACCF SPVE PKVE SBSM FCBL
2006 1006
FCBL (#0) During full-closed feedback, backlash
compensation is:
0: Applied to the position
1: Not applied to the position
⇒ See Subsecs. 4.6.4 and 4.6.5.
SBSM (#1) An amplifier whose input voltage is
200 V (standard) or 60 V is used:
0: Uses an amplifier whose input
voltage is 200 V (standard).
1: Uses an amplifier whose input
voltage is 60 V.
⇒ See Sec. 4.16.
PKVE (#2) Speed-dependent current loop gain
variable function is:
0: Not used
1: Used ← ★: Do not change
Related parameters:
1967 (Series 15), 2074 (Series
16), and 1074 (Power Mate-E)
SPVE (#3) A separate position detector is:
⇒ See Sec. 4.16.
0: Not used
1: Used