2.PMC SPECIFICATIONS B-63983EN/01
- 100 -
2.3.2 PMC Parameter Format
This subsection describes the format used in outputting the contents of
the PMC parameter to an external device. As for the operation of output,
refer to section 7 “sequence program and PMC parameter I/O”.
(1) Header information
The data begins with header information. Its format is as follows:
[Format]
%; (PMC = xxx, MSID = n)
PMC = xxx "xxx" is the model name of the PMC.
MSID = n "n" is ID information.
The following table lists values that can be set as "xxx" or "n".
30i/31i/32i-A
First PMC Second PMC
(option)
Third PMC
(option)
Dual-check
Safety PMC
(option)
30i 31i 32i 30i 31i 32i 30i 31i 32i 30i 31i 32i
xxx 30I-A 31I-A 32I-A 30I-A 31I-A 32I-A 30I-A 31I-A 32I-A 30I-A 31I-A 32I-A
n1 2 3 9
(2) Timer (T)
[Format]
N60xxxx Pnnnnn; Timer setting
N Sum of the timer address (T) offset and 600000.
The sum can range from N600000 to N600xxx and
from N609000 to N609xxx. "xxx" can take the
values listed below.
P Timer address value in decimal notation. It can
range from 0 to 32767 for a range of N600000 to
N600498.
(Example)
N600000 P1; (Timer number 1 T0)
N600002 P20; (Timer number 2 T2)
.
N600498 P32767; (Timer number 250 T498)
N609000 P0; ( T9000)
N609002 P0; ( T9002)
.
N609498 P0; ( T9498)
NOTE
At present, N609000 to N609xxx are a reserved
area, and P0 is set up for it.