Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
31/92
DRAW.NO.
6.2 DISPLAYING AND SETTING CONFIGURATION
PARAMETERS ([CONFIG PARAM] SCREENS)
Modify "9.9 DISPLAYING AND SETTING CONFIGURATION PARAMETERS ([CONFIG PARAM]
SCREENS) " as follows
Configuration parameter setting screens display the following NC
parameters related to PMCs in an easy-to-understand manner and
facilitate setting.
No. Settings Remarks
11900 to
11902
Execution priorities of multiple PMCs LADDER EXEC screen
11905 to
11907
Execution ratios of multiple PMCs LADDER EXEC screen
11910 to
11913
Input/output addresses of the I/O
Link
MACHINE I/F screen
11920 to
11929
G/F addresses of the CNC interface CNC I/F screen
11930 Level-1 execution cycle LADDER EXEC screen
11931 Start/stop mode of multiple PMCs LADDER EXEC screen
11941 PMC Memory type PMC MEMORY screen
CAUTION
1 For details of each CNC parameter, see Subsection
2.4.3 of PMC Programming Manual.
2 After setting these CNC parameters, turn the power
off, then on again.