5.WINDOW FUNCTIONS B-63983EN/02
- 616 -
5.7.6 Reading Tool Management Data (Low-speed Response)
[Description]
The tool management data is read, based on the specified cartridge
number, pot number, or tool management data number. In the case of
a free pot (a tool management data number is not assigned), error code
9 is returned.
NOTE
Customized data 5 to 20 can be read when the "tool
management function customized data extension (5
to 20)" option is present. Customized data 5 to 40
can be read when the "tool management function
customized data extension (5 to 40)" option is
present.
[Input data structure]
Top address + 0
+2
+4
+6
+8
+10
(Function code)
334
(Completion code)
-
(Need not be set)
(Data length)
-
(Need not be set)
(Data number)
Cartridge number
(Data attribute)
-
(Need not be set)
(Data number 2)
Pot number
+12
+14
(Detailed completion code)
-
Need not be set
(Data area)
76, 140, 220
[Completion codes]
0: The processing has been executed normally.
3: The specified cartridge number or pot number is invalid.
6: The necessary option is not found.
7: The area is protected.
9: Free pot.