7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 762 -
· setting-number Numeric data
The numbers (starting with 1) assigned to setting items
in ascending order are output.
· setting-item-name Character string data
The character string of each setting item is output.
· setting Numeric data
A value that is originally numeric, such as a resolution
value, is directly output. Numbers (starting with 1) are
assigned from left to right to options from which a
choice is to be made, such as TIME CYCLE/SIGNAL
TRANSITION, and the number assigned to a selected
option is output.
· setting-character-string Character string data
For a setting that is numeric data, its unit, if used, is
output.
For an option that is converted to a number in the item of
"setting" mentioned above, the original character string
data is output. In other cases, a blank is output in this
column.
Table of data of the first parameter setting page
Item Setting
number
Setting item name Setting Setting character string
1'TIME CYCLE'
Sampling mode 1 'Sampling mode'
2 'SIGNAL TRANSITION'
Sampling resolution 2 'Sampling resolution' Numeric value 'MSEC'
Sampling time 'Sampling time'
Sampling frame
3
'Sampling frame'
Numeric value 'SEC'
1 'NONE'
Stop condition 4 'Stop condition' 2 'BUFFER FULL'
3 'TRIGGER'
Stop trigger address 5 'Stop trigger address' Address Symbol
1 'RISING EDGE'
Stop trigger mode 6 'Stop trigger mode' 2 'FALLING EDGE'
3 'BOTH EDGE'
Stop position 7 'Stop trigger position' Numeric value %
1 'TRIGGER'
Sampling condition 8 'Sampling condition'
2 'ANY CHANGE'
Sampling trigger address 9 'Sampling trigger address' Address Symbol
1 'RISING EDGE'
Sampling trigger mode 10 'Sampling trigger mode' 2 'FALLING EDGE'
3 'BOTH EDGE'