B-63983EN/02 3.I/O LINK
- 179 -
· Configuration C
A machine which has the configuration A on channel 1 and two
beta amplifiers on channel 2.
Channel 1
CNC
Distribution I/O machine
operator's panel
Connection panel I/O
Group 0 Group 1
Channel 2
CNC
Group 0
Beta amp.
Group 1
Beta amp.
These machines can use a common sequence program which has I/O
link assignment data that includes all I/O device configurations. The
contents of parameters for each I/O device configuration are as shown
below.
(1) The contents of I/O link assignment data in sequence program
Channel 1
Address Group Base Slot Name I/O device
X0000 0 0 1 CM12I Distribution I/O machine
operator’s panel
::::: :
X0020 1 0 1 CM03I Connection panel I/O
::::: :
X0030 2 0 1 FS08A Power Mate
::::: :
Channel 2
Address Group Base Slot Name I/O device
X0200 0 0 1 OC02I Beta amp.
::::: :
X0220 1 0 1 OC02I Beta amp.
::::: :