4.1 AXIS INFORMATION
4.1.1 Reading the Servo Delay for Controlled Axes (High-speed
Response)
Replace the "5.5.5 Reading the Servo Delay for Controlled Axes (High-speed Response)".
[Description]
The servo delay, which is the difference between the specified
coordinates of CNC-controlled axes and the actual servo position, can be
read.
[Input data structure]
Top Address +0 (Function code)
30
+2
(Completion code)
-
(Need not to be set)
+4
(Data length)
-
(Need not to be set)
+6
(Data number)
N
(N=Unit)
N = 0: Read with Input unit
1: Read with Detection unit
+8
(Data attribute)
M
(M=Axis number)
M = 1 to n: Axis number
-1: All axes
+10
+n
(Data area)
-
(Need not to be set)
[Completion codes]
0: The servo delay for the controlled axes have been read normally.
3: The data number is invalid.
4: The data specified as the data attribute is invalid because it is neither
-1 nor a value from 1 to n (n is the number of axes). Alternatively,
the specified axis number is greater than the number of controlled
axes.