B-63983EN/02 9.PMC CONFIGURATION DATA SETTING SCREENS ([PMC CONFIG])
- 943 -
(2) Screen operations using other keys
Cursor keys
Use them to change the CNC-PMC interface block to be set.
INPUT key
You can also set an item by entering a numeric value or string
and pressing the INPUT key.
To set a PMC
· Enter PMC1, PMC2, or PMC3.
· Enter a numeric value 1, 2, or 3.
To set G/F addresses
· Enter a displayed string such as G0000/F0000.
· Enter a start address such as 0, 1000, or 2000.
CAUTION
1 You can set an item on this screen regardless of the
NC mode.
2 If data is duplicate, the data is displayed in red and
the following message appears:
"DUPLICATE G/F ADDRESS"