6.OPERATING THE PMC SCREEN B-63983EN/02
- 636 -
PROGRAMMER ENABLE (K900.1)
If you set "PROGRAMMER ENABLE" to "YES", it enables the
following functions as a supervisor mode.
· Ladder editing screen
· Title data editing screen
· Symbol/comment data editing screen
· Message data editing screen
· I/O unit address setting screen
· Clear of PMC parameter
· Start/stop of ladder
· Forcing function
· Override function*1
· Setting of multi-language message display function
· Data I/O screen
· System parameter screen
· Parameter setting screen for online monitor
· Setting screen for the I/O link assignment data selection function
· Setting screen for keep relay K900 or after
· Configuration parameter screen
· Sequence program input and output
· PMC parameter input and output
· Input and output of message data for multi-language display
· Saving of a sequence program to flash ROM
· Saving of message data for multi-language display to flash ROM
NOTE
The override function also requires the setting of
"OVERRIDE ENABLE" in the setting parameters.
CAUTION
Set this setting to "NO"(0) before shipment of the
machine. If this setting is left as "YES"(1), the
operator may stop execution of the ladder program
by mistake. If you want to protect this setting,
please make a sequence that always writes 0 in this
bit by your ladder. Or please control the machine to
force to translate into safety state by sequence
program using the way described in Section 4.15
when the ladder stops.