5.WINDOW FUNCTIONS B-63983EN/02
- 554 -
5.6.16 Writing Tool Life Management Data (Tool Life Counter)
(Low-speed Response)
[Description]
This function sets the tool life counter in the specified tool group in
the tool life management data.
[Input data structure]
Top address + 0
+2
+4
+6
+8
+10
(Function code)
165
(Completion code)
-
(Need not be set)
(Data length)
4
(Data number)
N
(N = Tool group number)
(Data attribute)
0
Tool life counter (4 bytes)
Value
Unsigned binary
1–65535 times (Number of uses)
1–4300 minutes (Real time) Note
With the tool life management B function
1–99999999 times (Number of uses)
1–100000/60000 minutes (Real time) Note
NOTE
CNC parameter FCO(6805#0) decides the unit of
tool life value of real time counter type as follows:
6805#0 = 0 : 1 minute (1–4300)
6805#0 = 1 : 0.1 minute (1–43000)
With the tool life management B function, this
parameter also decides the effective region of life
value as follows:
6805#0 = 0 : 100000 minutes (1–100000)
6805#0 = 1 : 60000 minutes (1–600000)
[Completion codes]
0: Succeeded to set the tool life counter.
3: The specified tool group number is incorrect.
5: The value for tool life counter is out of range.
6: No option for the tool life management.