7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 684 -
(f) [ADRESS] Address display switching
Displays the start address of a data table in the ADDRESS
column.
This soft key is valid for symbol display.
(g) [INIT] Data table control data initialization
Initializes the setting of data table control data.
NO. ADDRESS PARAMETER TYPE DATA
1 D0000 00000000 0 10000 (NOTE)
NOTE
1 When data table control data is initialized, the entire
data area is set as a single table. The start address
is the start address of the D addresses. The control
parameters are set as follows: signed binary format,
without input protection, one-byte data size, and the
number of data items set to the total number of
bytes in the entire D address area.
2 The initial number of data items for the first PMC is
10000. For the second PMC, third PMC, and the
PMC for dual check safety, the initial number of
data items is 3000.
(h) [PARAM] Switching to the soft keys for parameter setting
Switches to the soft keys for setting the parameters of data
table control data.
(i) [TYPE] Switching to the soft keys for data setting
Switches to the soft keys for data size setting.
(j) [SWITCH PMC] PMC path switching
Switches PMC paths.
This soft key is effective to multi-PMC systems only.
(k) [SGNDEC] Setting for signed decimal
Sets signed decimal for the parameters of data table control
data.
(l) [USDEC] Setting for unsigned decimal
Sets unsigned decimal for the parameters of data table
control data.
(m) [BCD] Setting for BCD
Sets BCD for the parameters of data table control data.
(n) [HEX] Setting for hexadecimal
Sets hexadecimal for the parameters of data table control
data.
(o) [PROTECT] Protection state modification
Modifies the protection state of the parameters of data table
control data.
(p) [BYTE] Setting for byte
Sets the data size to one byte.
(q) [WORD] Setting for word
Sets the data size to two bytes.