B-63983EN/02 3.I/O LINK
- 155 -
(2) Basic module + expansion module 1
Basic
module
JD1B
JD1A
Expansion
module 1
48 input points, 32 output points
(a) When DO alarm detection is not used
· When no manual pulse generator is used
Input: X=CM06I, output: Y=CM04O
· When one manual pulse generator is used
Input: X=CM13I, output: Y=CM04O
(b) When DO alarm detection is used
· Regardless of the number of manual pulse generators
Input: X=CM16I, output: Y=CM04O
(3) Basic module + expansion module 1 + expansion module 2
Basic
module
JD1B
JD1A
Expansion
module 1
Expansion
module 2
72 input points, 48 output points
(a) When DO alarm detection is not used
· When no manual pulse generator is used
Input: X=CM09I, output: Y=CM06O
· When one manual pulse generator is used
Input: X=CM13I, output: Y=CM06O
· When two manual pulse generators are used
Input: X=CM14I, output: Y=CM06O
(b) When DO alarm detection is used
· Regardless of the number of manual pulse generators
Input: X=CM16I, output: Y=CM06O