B-63983EN/02 9.PMC CONFIGURATION DATA SETTING SCREENS ([PMC CONFIG])
- 947 -
CAUTION
When the NC parameters are all set to 0, the initial
status (for the initial status, see (e)) is set. Deleting
all items with this operation is equivalent to setting
the initial status. For this reason, if an attempt is
made to delete the last item, the following message
appears and the item cannot be deleted:
"LAST SETTING DATA CAN NOT BE DELETED."
(c) [MENU] Switch to the MENU screen
Switches to the MENU screen.
(d) [INIT] Initialize settings
Initializes the interface settings.
This soft key is displayed and can be operated only when
editing is allowed.
The initial settings are as follows:
(2) Screen operations using other keys
Cursor keys
Use them to change the I/O Link channel to be set.
INPUT key
You can also set an item by entering a numeric value or string
and pressing the INPUT key.
To set a PMC
· Enter PMC1, PMC2, PMC3, or PMCDCS.
· Enter a numeric value 1, 2, 3, or 9.
To set X/Y addresses
· Enter a displayed string such as X0000/Y0000.
· Enter a start address such as 0, 200,400 or 600.
CAUTION
1 You can set an item on this screen regardless of the
NC mode.
2 If data is duplicate, the data is displayed in red and
the following message appears:
"DUPLICATE X/Y ADDRESS"