[Output data structure]
Top Address +0 (Function code)
409
+2 (Completion code)
?
(See above description)
+4 (Data length)
24
+6 (Data number)
N
(N=Same as input data)
+10 (Data attribute)
M
(M=Same as input data)
+12 (Detailed completion code)
(See above description)
+14 Tool type number
(4byte)
This is the same as "N: Data number" which you
specify.
+18 Total life counter
(4byte)
The unit of this data is indicated by "+37: Life
count type".
+22 Total remaining life
(4byte)
The unit of this data is indicated by "+37: Life
count type".
+26 Total maximum life
(4byte)
The unit of this data is indicated by "+37: Life
count type".
+30 Total notice life
(4byte)
The unit of this data is indicated by "+37: Life
count type".
+34 Tool count
(2byte)
The tools, which have the specified tool type
number and tool life type, are counted.
+36 Total life status
(1byte)
0: Not noticed, 1: Noticed
+37 Life count type
(1byte)
0: Count, 1: Time (second), 2: Time