[Input data structure]
Top Address +0 (Function code)
420
+2 (Completion code)
-
(Need not to be set)
+4 (Data length)
0
+6 (Data number)
N
(N=Search kind number)
+8 (Data attribute)
-
(Need not to be set)
+10 (Data number 2)
-
(Need not to be set)
+12 (Detailed Completion code)
-
(Need not to be set)
+14 Search data 1
(4 bytes)
+18
+21
Search data 2
(4 bytes)
[Completion codes]
0: The processing has been executed normally.
3: The specified magazine number, pot number or tool
management data number is invalid.
6: The necessary option is not found.
7: The area is protected.
9: Free pot.
[Detailed completion codes]
The detailed completion code is always 0 when the completion code is
other than 3.
When the completion code is 3, the detailed completion code is one of the
following values:
100: The specified Search kind number is invalid.
101: The specified Search data 1 is invalid.
102: The specified Search data 2 is invalid.
103: The specified tool is not found.