7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 694 -
· WRITE CODE
"WRITE CODE" is displayed when "OTHERS" is selected for
"DEVICE".
ASCII: Sets the output code to "ASCII".
ISO: Sets the output code to "ISO".
NOTE
Parity is always "NONE".
Fig. 7.4.2 Soft keys on the port setting screen
Explanation of soft keys
(1) [INIT] Setting initialization
Sets all the parameters to their initial values.
The table below indicates the initial value of each setting item.
Initial values
DEVICE DEVICE = FLOPPY DEVICE = OTHERS
CHANNEL 1 1
BAUD RATE 4800 4800
STOP BIT 2 BITS 2 BITS
WRITE CODE (NONE) ISO
(2) [I/O] Switching to the I/O screen
Terminates the setting of the communication parameters and
switches the screen display to the I/O screen.
Operation of the return key
On the port setting screen, the operation of the return key is disabled.
Use the [I/O] soft key to terminate the setting of the communication
parameters and return to the I/O screen.
Soft keys on the port setting screen
Setting initialization Switching to the I/O screen