7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 724 -
7.4.20 Outputting PMC Parameters to the FLOPPY
PMC parameters can be output from a PMC to a Floppy Cassette or
Handy File connected via RS-232C. To use this function, perform the
operation described below on the I/O screen. To set the
communication parameters, display the port setting screen by pressing
the [PORT SETING] soft key. For the port setting screen, see
Subsection 7.4.2.
NOTE
This operation can be performed only when the
operation condition allows PMC parameter output.
For details, see Section 6.2.
(1) On the I/O screen, make the following settings with the query
selection cursor and option selection cursor:
Query Setting
PMC (Output target PMC)
DEVICE FLOPPY
FUNCTION WRITE
KIND OF DATA PARAMETER
For the setting of an output target PMC, see Subsection 7.4.4.
(2) Move the query selection cursor to FILE NAME, then enter a
desired file name.
For output to a FLOPPY in the DOS format, enter a file name not
longer than eight characters with an extension not longer than
three characters in the MS-DOS format. For output to a
FLOPPY in the FANUC format, enter a file name not longer than
seventeen characters. When no file name is entered, the
following file name is automatically set:
Output target PMC File name
PMC1 PMC1_PRM.000
PMC2 PMC2_PRM.000
PMC3 PMC3_PRM.000
Dual check safety PMCS_PRM.000
If a file with the same file name already exists, the extension
number is incremented for output.
Example:
PMC1_PRM.001
(3) Press the [EXEC] soft key to output the PMC parameters.