Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
81/92
DRAW.NO.
8.3.7 Writing a Specified Type of Tool Management Data (Low-speed
Response)
[Description]
A specified type of tool management data is written to memory.
Enter the data type number to be written, as the data attribute.
The size of the required data area varies depending on the data type.
The following table shows the relationship between each data type
number and its corresponding data and required data area size.
Table 8.3.7 Data, data type number and data area size
Data type
number
Data Data
area size
Remarks
1 Tool type number 4 bytes
2 Tool life counter 4 bytes
3 Maximum tool life 4 bytes
4 Notice tool life 4 bytes
5 Tool life status 1 byte
6 Customized data 0 1 byte
7 Tool information 2 bytes
8 Tool length compensation number
(H)
2 bytes * for milling or compound system
9 Cutter compensation number (D) 2 bytes * for milling or compound system
10 Spindle speed (S) 4 bytes
11 Cutting feedrate (F) 4 bytes
12 Tool geometric compensation
number (G)
2 bytes * for lathe or compound system
13 Tool wear compensation number (W) 2 bytes * for lathe or compound system
14 Tool geometry number (GNO) 2 bytes The option "Tool life management function (oversize
tools supported)" is necessary.
31 Customized data 1 4 bytes
~ ~ ~ ~
34 Customized data 4 4 bytes
35 Customized data 5 4 bytes
~ ~ ~
50 Customized data 20 4 bytes
These data are available when the option "Tool
management function customized data extension (5
to 20)" or "Tool management function customized
data extension (5 to 40)" is equipped.
51 Customized data 21 4 bytes
~ ~ ~
70 Customized data 40 4 bytes
These data are available when the option "Tool
management function customized data extension (5
to 40)" is equipped.