5.2 PARAMETERS FOR THE PMC SYSTEM
5.2.1 CNC Parameters Related to the PMCs
Add the following to "2.4.3 CNC Parameters Related to the PMCs"
PMC Memory Type
11941 PMC Memory Type of 2nd PMC
NOTE
Once any of these parameters is re-set, it is necessary
to turn the power off and on again.
[Data type] Integer
[Valid data range] 0, 1, 2
Select a PMC Memory Type of each PMC path. Refer to the 5.1.1(b) of
"5.1.1 Basic specification" for details of each PMC Memory Type.
Setting Meaning
0 Use standard setting of PMC Memory.
1 Use PMC Memory-A
2 Use PMC Memory-B
In the standard setting, the PMC Memory Type is as follows.
PMC Path PMC Memory Type
2nd PMC PMC Memory-A
CAUTION
1 Setting an invalid value to this parameter results in the
PMC alarm "ER58 PMC MEMORY TYPE SETTING
ERROR" and all sequence programs for each PMC
will not be started.
2 PMC nonvolatile memory must be initialized after
changing PMC Memory Type. Therefore, please
make a backup of PMC parameter before changing
PMC Memory Type. Refer to the "2.7 DATA
BACKED UP BY THE BATTERY" of PMC
Programming Manual about the operation of
initializing PMC nonvolatile memory.