B-63983EN/01 2.PMC SPECIFICATIONS
- 109 -
2.4.2 PMC System Parameters
The parameters set up on the PMC SYSTEM PARAMETER screen are
called the system parameters.
This subsection describes the system parameters for each setup menu.
See Section 9.8 for explanations about the how to operate the SYSTEM
PARAMETER screen.
(1) Counter type
This item specifies the data type of a counter value used on the
COUNTER screen (CTR functional instruction). It can be
represented in either binary or BCD form.
(2) FS0-compatible operator's panel
This item specifies whether to connect an operator's panel for the
FS0. If the setting is "Yes", specify also the DI/DO address to
which the operator's panel is actually connected, the address of the
KEY image transferred from the operator's panel, and the address
of the LED image to be transferred to the operator's panel.
(a) DI address
This item specifies the start address of the external DI to
which the operator's panel is actually connected, using PMC
addresses (X0 to X127, X200 to X327, X400 to X527, or
X600 to X727).
(b) DO address
This item specifies the start address of the external DO to
which the operator's panel is actually connected, using PMC
addresses (Y0 to Y127, Y200 to Y327, Y400 to Y527, or
Y600 to Y727).
(c) Key input image address
This item specifies the start address of the KEY image to be
referenced by the user program, using a PMC address.
Usually, set up an arbitrary internal relay (R) area.
(d) LED output image address
This item specifies the start address of the LED image
generated by the user program, using PMC addresses.
Usually, set up an arbitrary internal relay area (R).
(3) Selectable I/O Link assignment function
This item specifies whether to enable/disable the selectable I/O
Link assignment function for each address and the number of the
related basic groups.
(a) Function enable
This item specifies whether to enable/disable the selectable
I/O Link assignment function.