7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE]) B-63983EN/02
- 778 -
NOTE
If the Forced I/O function is protected by the programmer
protection function, this setting is not effective.
The Forced I/O function will be protected in the condition
as follows.
In case of Programmer Protection Function
· PROGRAMMER ENABLE (K900.1) "NO"
and
· RAM WRITE ENABLE (K900.4) "NO"
In case of Protection of Data at 8 Levels
· Operation level is less than CHANGE level of “PMC
MEMORY”.
SHOW PROGRAM
Determines the form of symbol name in the I/O Diagnosis screen.
SYMBOL: Symbol names are displayed in the form below:
<Program Symbol>.<Signal Simbol>
If symbol name is too long for the symbol field of the
I/O Diagnosis screen, the tail of signal symbol is cut to
fit it.
PROGRAM NO.:Symbol names are displayed in the form below:
<Program Number>.<Signal Simbol>
If symbol name is too long for the symbol field of the
I/O Diagnosis screen, the tail of signal symbol is cut to
fit it.
NONE: Program symbol nor program number is not displayed.
NOTE
These setting data are kept in the nonvolatile memory
not to be lost even if the power is turned off.