9.PMC CONFIGURATION DATA SETTING SCREENS ([PMC CONFIG]) B-63983EN/02
- 872 -
(2) Editing a set of symbol and comment data at a time
An address, symbol, and comment are input at a time.
Enter a symbol and comment following an address with
delimiting them by non-alphanumeric characters as shown below
and press the INPUT key. Symbol or comment data can be
omitted.
address/symbol/comment/ INPUT key ("/" is a non-
alphanumeric character.)
Example 1: Inputs an address, symbol, and comment. A slash
“/” is used as a delimiter.
G0.4/*EMG/EMERGENCYSW/INPUT key
Example 2: Omits a comment. A slash “/” is used as a delimiter.
G0.4/*EMG//INPUT key
G0.4/*EMG/ INPUT key
G0.4/*EMG INPUT key
To update symbol or comment data for an existing address, move
the cursor to the target address and enter symbol or comment
data with omitting the address.
Example 3: Omits an address and inputs symbol and comment
data. A slash “/” is used as a delimiter.
/*EMG/EMERGENCYSW/INPUT key
In this case, when symbol or comment data is omitted, the
displayed data is not changed.
(3) Screen operations using other keys
Cursor keys: Move the cursor.
Page keys: Scroll the screen up or down one page.
(4) RETURN key operation
On the SYMBOL & COMMENT DATA EDITOR screen, the
return key operation is disabled.
To terminate editing of symbol and comment data and return to
the SYMBOL & COMMENT DATA VIEWER screen, use the
[EXIT EDIT] soft key.