5.WINDOW FUNCTIONS B-63983EN/02
- 442 -
[Completion codes]
0: Setting data has been read normally.
3: The setting number specified for reading is invalid.
4: The specified data attribute is invalid because it is neither 0, -1, nor
a value from 1 to n (n is the number of axes).
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
19 or 155
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 1, 2, 4, 1*n, 2*n, 4*n)
(Data number)
N
(N = Input data)
(Data attribute)
M
(M = Input data)
Setting data
Parameter-dependent form
Value
L = 1: Bit or byte parameter
L = 2: Word parameter
L = 4: Double word parameter
When no axis or one axis is specified
When all axes are specified
L = 1*n: Bit or byte parameter
L = 2*n: Word parameter
L = 4*n: Double word parameter