3.3.10 Reading Magazine Property Data (Low-speed Response)
Add "Reading Magazine Property Data (Low-speed Response)" to "5.7 TOOL MANAGEMENT FUNCTIONS".
[Description]
Reading magazine property data with specified magazine number.
[Input data structure]
Top Address +0 (Function code)
424
+2 (Completion code)
-
(Need not to be set)
+4 (Data length)
-
(Need not to be set)
+6 (Data number)
N
(N=Magazine number)
+8 (Data attribute)
-
(Need not to be set)
+10 (Data number 2)
-
(Need not to be set)
+12 (Detailed completion code)
-
(Need not to be set)
+14
+37
Data area
(24 bytes)
(Need not to be set)
[Completion codes]
0: The processing has been executed normally.
3: The specified magazine number is invalid.
6: The necessary option is not found.
[Detailed completion codes]
The detailed completion code is always 0 when the completion code is
other than 3.
When the completion code is 3, the detailed completion code is one of the
following values:
21: The specified magazine number is invalid.