Series 30i/ 31i/ 32i-MODEL A
PMC Supplemental Programming Manual
01 04.12.27
S. Hasegawa
New registration
B-63983EN/02-3
EDIT
DATE
DESIG.
DESCRIPTION
67/73
DRAW.NO.
Modify the title of the section "8.9 DETECTION OF DOUBLE COILS" to "8.9 CHECKING OF DUPLICATE
COIL ([DUP. CHECK] SCREEN)"
Add the following section "8.10 CHECKING OF DUPLICATE COIL ([DUP. CHECK] SCREEN)" after the "8.9
CHECKING OF DUPLICATE COIL ([DUP. CHECK]) SCREEN"
8.1 CHECKING OF DUPLICATE COIL ([DUP. CHECK] SCREEN)
On the Duplicate Coil Check screen, you can check the overwriting of a
PMC address from some coil instructions. And, you can check the
multiple use of instruction number of the following numbered functional
instructions.
Instruction name SUB number Function
TMR 3 Timer
TMRB 24 Fixed Timer
TMRBF 77 Off Delay Fixed Timer
CTR 5 Counter
CTRB 56 Fixed Counter
DIFU 57 Rising Edge Detection
DIFD 58 Falling Edge Detection
Moreover, you can check the overwriting of a common memory (E
address) from some PMC paths when using a multiple PMC paths
system.
The result of check is displayed with a list of net numbers of a program
that is using duplicated data.
You can display a selected ladder net by moving the cursor and pressing
the [JUMP] soft key.