8.LADDER DIAGRAM MONITOR AND EDITOR SCREENS ([PMC LADDER]) B-63983EN/02
- 808 -
·
··
· Functional instructions of special monitor format
Displays instructions in the following format:
Functional instructions Functional instruction
Vertical display horizontal display
Timer number = Current value Timer number
Preset value Current value
Preset value
The monitor display format of the preset values and the
current values varies depending on the timer precision, as
given in the table below. For details of timer precision, see
Subsection 7.3.1.
Precision Resolution Display format
0 8 msec/48 msec by second
1 1 msec by second
2 10 msec by second
3 100 msec by second
4 1 second HH:MM:SS
5 1 minute HH:MM:SS
TMR
TMRB
Displays current value by seconds (HH:MM:SS if 1 minute or
more) (preset value is displayed by milliseconds)
The 2nd parameter shows preset value, and the 3rd
parameter shows current value as their monitor displays.
These two monitor displays changes their format according
to the 1st parameter as below:
1st parameter Resolution Display format
0 8 msec by second
1 48 msec by second
2 1 second HH:MM:SS
3 10 seconds HH:MM:SS
4 1 minute HH:MM:SS
5 1 msec by second
6 10 msec by second
7 100 msec by second
TMRC
CTR
Displays in "Current/Preset" format by binary or BCD
according to the counter type setting in LADDER Program.
CTRB Monitors and displays preset values in binary mode.
CTRC Monitors and displays preset values in binary mode.