Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 05.03.30
H. Yonekura
New registration
B-63983EN/02-4
EDIT
DATE
DESIG.
DESCRIPTION
25/92
DRAW.NO.
5.3 Compatibility with Conventional Models
Insert the following before "2.5.1 Compatibility with the PMCs for the 16i/18i/21i-B"
5.3.1 Compatibility between PMC Memory-A and PMC Memory-B
The sequence program for the PMC Memory-B has highly compatiblity
of the source program with the one for the PMC Memory-A.
You can convert a sequence program for the PMC Memory-A to one for
the PMC Memory-B using the conversion function of FANUC
LADDER-III.
CAUTION
A little difference of execution timing exists between
PMC Memory Types. Therefore, you have to check
again whether the program works correctly after
changing the PMC Memory Types even if the
program worked fine before changing the PMC
Memory Types.
PMC Parameter compatibility
A PMC parameter outputted from on the PMC Memory-A can be loaded
on the PMC Memory-B without any modification.
When loading a PMC parameter outputted on the PMC Memory-B to the
PMC Memory-A, the data outside the address range will be lost.