B-63983EN/02 7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE])
- 769 -
NOTE
This screen shows the I/O information according to
the network setting that became effective at the
time of the last power-on.
The notes for each network device are as follows:
PROFIBUS
1. If you have changed some of the profibus
parameters, you have to cycle the power once to
make the changes take effect.
I/O LINK
1. Only the I/O Link assingments, which are made
effective by the setting of “Machine Signal Interface”
in Configuration Parameter menu and the setting of
“Selectable I/O Link Assignment Function”, are
displayed.
2. If you have changed the following parameters, you
have to cycle the power once to make them take
effect:
· “I/O module assignment data”
· “Machine signal interface” in PMC configuration
parameter
· “Selectable I/O Link assignment function”
3. If you have stored new sequence program to PMC,
its I/O Link assignment data will not take effect until
you write it into Flash-ROM and cycle the power
once.
Status: the status of communication
“OK” or “NG” is displayed.
REMARK
The remarks up to 8 characters extracted from comment data are
displayed. To specify the remark at this field, set “100” to the
attribute value of the comment, which you want to show in this field,
on FANUC LADDER-III,