4.LADDER LANGUAGE B-63983EN/02
- 356 -
(9) 9th path
CTL+0 : 9
CTL+1 to CTL+3 : Data to be specified for G8000 to G8002
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G8000 to G8001
CTL+3 to CTL+4 : Data to be specified for G8210 to G8211
CTL+5 : Data to be specified for G8002
(10) 10th path
CTL+0 : 10
CTL+1 to CTL+3 : Data to be specified for G9000 to G9002
In case of the extended specification (program number O8 digits
etc.), it sets CTL+1 to CTL+5 as follows.
CTL+1 to CTL+2 : Data to be specified for G9000 to G9001
CTL+3 to CTL+4 : Data to be specified for G9210 to G9211
CTL+5 : Data to be specified for G9002
NOTE
Refer to the NC connecting manual for detailed data
to be specified concerning external data input.