Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 '05.12.26
H. Yonekura
New registration
B-63983EN/02-8
EDIT
DATE
DESIG.
DESCRIPTION
17/32
DRAW.NO.
Replace the "5.4.17 Reading Modal Data (High-speed Response)" as follows.
3.1.5 Reading Modal Data (High-speed Response)
Using this function, you can read modal information of CNC.
Reading modal infomation of G-function (Data number=0 to 33, -1)
[Description]
Using this function, you can read modal information of G-function.
[Input data structure]
Top Address +0 (Function code)
32
+2 (Completion code)
-
(Need not to be set)
+4 (Data length)
-
(Need not to be set)
+6 (Data number)
N
(N=Data type)
N =0 to 33: Each data reading (See. Table 3.1.5 (a))
=-1: Collective reading (Group No.0 to 31)
+8 (Data attribute)
M
(M=Specified block)
M =0: Current block
=1: Next block
=2: (reserved)
+10
(Data area)
-
(Need not to be set)
NOTE
1 A modal information for a block after the next block
cannot be read.
2 When a collective reading, the read modal
information of groups are from No. 0 to No.31. To
read modal information of over No. 31 group, use the
each data reading by setting over 31 to the data
nubmer N.