3.6 PMC CONFIGURATION PARAMETER SETTING SCREEN
Modify the table of "9.9 DISPLAYING AND SETTING CONFIGURATION PARAMETERS ([CONFIG
PARAM] SCREENS)" as follows
3.7 DISPLAYING AND SETTING CONFIGURATION
PARAMETERS ([CONFIG PARAM] SCREENS)
Configuration parameter setting screens display the following NC
parameters related to PMCs in an easy-to-understand manner and
facilitate setting.
No. Settings Remarks
11900 to
11902
Execution priorities of multiple
PMCs
LADDER EXEC screen
11905 to
11907
Execution ratios of multiple
PMCs
LADDER EXEC screen
11910 to
11913
Input/output addresses of the I/O
Link
MACHINE I/F screen
11915 to
11918
Input/output address of dual
assignment of I/O Link channel
MACHINE I/F screen
11920 to
11929
G/F addresses of the CNC
interface
CNC I/F screen
11930 Level-1 execution cycle LADDER EXEC screen
11931 Start/stop mode of multiple
PMCs
LADDER EXEC screen
Modify "9.9.3 Setting the Machine Signal Interface" partially as follows
3.7.1 Setting the Machine Signal Interface
On the PMC CONFIGRATION PARAMETER (MACHINE
INTERFACE) screen, set the input/output addresses of the I/O Link.
CAUTION
1 For details of input/output addresses of the I/O Link,
see the description of input/output addresses of the
I/O Link in Subsection 2.4.3.
2 For details of input/output addresses for virtual
channels of the I/O Link channel split function, see
the description of Input/output addresses of dual
assignment of I/O Link channel in Subsection 2.4.3.