2.PMC SPECIFICATIONS B-63983EN/01
- 112 -
Communication parameters
00024 Setting up communication with ladder development tools (FANUC LADDER-
III and ladder editing package)
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 to 255
This item specifies whether to enable/disable the PMC online
connection function.
Entering this parameter makes it possible to enable/disable the PMC
online setup function without displaying the PMC online setup screen.
Setting RS-232C High-speed interface
0 The settings on the PMC online setup screen are
changed.
1 To be used (channel 1) Not to be used
2 To be used (channel 2) Not to be used
10 Not to be used To be used
11 To be used (channel 1) To be used
12 To be used (channel 2) To be used
255 Communication is forced to stop (equivalent to the [EMG
STOP] soft key).
NOTE
1 The setting of this parameter is put into effect when it
is changed or the power is turned on. It is
unnecessary to turn the power off and on again after
the parameter is re-set.
2 The setting changed on the PMC online setup screen
is not reflected to this parameter.
3 As for the RS-232C, the communication settings,
such as a baud rate, specified on the PMC online
setup screen are valid. The valid settings are a baud
rate of 9600 bps, no parity, and two stop bits if no
change has been made on the PMC online setup
screen since installation.