B-63983EN/02 7.PMC DIAGNOSIS AND MAINTENANCE SCREENS ([PMC MAINTE])
- 751 -
h) STOP CONDITION/ TRIGGER/ POSITION
When "TRIGGER" is set on "STOP CONDITION", this
parameter is enabled. Input the ratio of the sampling time or
number which specifies the position where specified trigger
condition is on. If you would like to examine the transitions of
the signal before the trigger condition, you should set a big value
in this parameter. If you would like to examine the transitions of
the signal after the trigger condition, you should set a small value
in this parameter.
Example: The case that sampling time is 10 seconds and trigger
position is set as "10%".
¬ 1 sec ®¬ 9 sec ®
Trigger position
(i) SAMPLING CONDITION
When "SIGNAL TRANSITION" is set on "TRACE MODE",
this parameter is enabled.
Determine the sampling condition.
· TRIGGER: Samples the status of specified signals
when the specified sampling condition is
on.
· ANY CHANGE: Samples the status of specified signals
when the signals change.
(j) SAMPLING CONDITION/ TRIGGER/ ADDRESS
When "SIGNAL TRANSITION" is set on "TRACE MODE",
and "TRIGGER" is set on "SAMPLING CONDITION", this
parameter is enabled. Input signal address or symbol name as
sampling trigger.
A PMC number can be set for a trigger address by entering the
PMC number at the time of address setting.
Example: 2:R9200.1 + Input key
A setting can be made by entering "PMC number" + ":" +
"address" as indicated above.
NOTE
1 For the PMC numbers, see Section 1.5.
2 If there is not “:” key in your keybord, use “;” or “/”.