9.PMC CONFIGURATION DATA SETTING SCREENS ([PMC CONFIG]) B-63983EN/02
- 918 -
9.7.1 Setting Parameters for the Online Function
The online function can be connected using one of the following three
methods.
Connection method Applicable software
Ethernet FANUC LADDER-III and Ladder Editing Package
RS-232C FANUC LADDER-III
HSSB Ladder Editing Package
Before using the online function, put the online function into the
connection waiting state on the PMC.
To put the PMC into the connection waiting state, use the
PARAMETERS FOR ONLINE MONITOR screen or relevant CNC
parameter.
To use Ethernet for connecting the online function, set Ethernet
communication parameters. For details of the Ethernet
communication parameters, see Subsection 9.7.3.
(1) Setting of online connection using the PARAMETERS FOR
ONLINE MONITOR screen
Press the [ONLINE] soft key to display the PARAMETERS
FOR ONLINE MONITOR screen.
NOTE
When the programmer protection function is
enabled, the online setting screen is available. For
details, see Section 6.2.