5.WINDOW FUNCTIONS B-63983EN/02
- 502 -
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
75
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 4*n. n is the number of
specified axes.)
(Data number)
-
--
-
(Data attribute)
M
(M: Input data)
Remaining travel along the
specified controlled axis (4 bytes)
Signed binary
(A negative value is represented in
2's complement.)
Value
When the number of controlled axes is 4
10
14
Remaining travel along the second
axis (4 bytes)
Signed binary
(A negative value is represented in
2's complement.)
Value
Remaining travel along the first
axis (4 bytes)
18
Remaining travel along the third
axis (4 bytes)
22
Remaining travel along the fourth
axis (4 bytes)
[Output data unit]
Increment system
Input
system
IS-A IS-B IS-C IS-D IS-E
mm, deg 0.01 0.001 0.0001 0.00001 0.000001
Machining center
system
inch 0.001 0.0001 0.00001 0.000001 0.0000001
Radius
specification
0.005 0.0005 0.00005 0.000005 0.0000005
Diameter
specification
mm, deg
0.01 0.001 0.0001 0.00001 0.000001
Radius
specification
0.0005 0.00005 0.000005 0.0000005 0.00000005
Lathe
system
Diameter
specification
inch
0.001 0.0001 0.00001 0.000001 0.0000001