Series 30i/31i/32i-MODEL A
PMC Supplemental Programming Manual
01 '05.10.5
H. Yonekura
New registration
B-63983EN/02-7
EDIT
DATE
DESIG.
DESCRIPTION
15/15
DRAW.NO.
(6) The nonvolatile memory control keep relay (MWRTF and
MWRTF2) has been changed from K16 to K909.
(7) In the PMC-SA1 and loader control PMCs, the keep relay system
area has been changed from "K17 to K20" to "K900 to K999".
(8) Window function "Reading diagnosis data" is a Low-speed
response type.
(9) When using Window function "No.30 Reading the servo delay for
controlled axes" with the data number N=0, the data is read with
input unit. When using the function with the data number N=1, the
data is read with detection unit. On Series 16i/18i/21i, the data is
always read with detection unit.
(10) When using Window function "No.31 Reading the acceleration /
deceleration delay on controlled axes" with the data number N=0,
the data is read with input unit. When using the function with the
data number N=1, the data is read with detection unit. On Series
16i/18i/21i, the data is always read with machine unit.
(11) A part of Window function for PMC-MODEL SB7 and SA1 is not
supported. See "5 Window function" for available window function.
(12) The contents of the completion codes for some window functions
are changed. See "5 Window function" for the completion codes.
(13) The MMCWR, MMCWW, and FNC90 to FNC97 functional
instructions are treated as a NOP.
(14) Programs can be created on the third level because of program
compatibility. The operations on the third level are not guaranteed
with respect to timing, however. Use only the first and second
levels in programming.
PMC parameter compatibility
Parameters prepared for conventional PMC models can be loaded to
30i/31i/32i-A PMC.
30i/31i/32i-A PMC has a smaller address range than the models
indicated as "Partly compatible" in Table 2.5.1. So the parameters
prepared for these models can be loaded partly into the 30i/31i/32i-A
PMC. Any data that does not fit the address range is discarded.
See Subsection 2.3.2.