8.3.3 Registering New Tool Management Data (Low-speed
Response)
[Description]
A new tool is registered, based on the specified cartridge number and pot
number, or tool management data number. The system searches for a
free area, starting from the top of the memory space, and registers the
specified tool management data in the free area found. A free area refers
to a location in the memory space where the tool management data is
disabled (bit 0 of the tool management data is set to 0). Error code 8 is
returned if there is no free area.
If the specified cartridge number or pot number does not correspond to a
free pot (a tool management data number is already assigned to it), error
code 13 is returned.
When the option "Tool management function (oversize tools supported)"
is equipped, you can also register the item "Tool geometry number" to
the tool management data. If you will register the tool management data
that causes an interference with another tool or cartridge frame, the
number 5 will be returned as completion code and number 27 will be
returned as detailed completion code.
NOTE
The data length varies depending on whether the
"Tool management function customized data
extension (5 to 20)" or "Tool management function
customized data extension (5 to 40)" option is
equipped or not.
(a) Data length
76: When the option "Tool management function customized data
extension" is not equipped.
140: When the option "Tool management function customized data
extension (5 to 20)" is equipped.
220: When the option "Tool management function customized data
extension (5 to 40)" is equipped.