[Output data structure]
When read a specified axis.
Top Address +0 (Function code)
31
+2 (Completion code)
?
(See above description)
+4 (Data length)
4
+6 (Data number)
N
(N=Same as input data)
+8 (Data attribute)
M
(M=Same as input data)
+10
+13
Acc./Dec. delay
(4 bytes)
Signed binary format in 4 bytes length.
When read all axes. (ex. number of controlled axes is 3)
Top Address +0 (Function code)
31
+2 (Completion code)
?
(See above description)
+4 (Data length)
12
+6 (Data number)
N
(N=Same as input data)
+8 (Data attribute)
-1
(Same as input data)
+10 ACC./Dec. delay of 1st axis
(4 bytes)
Signed binary format in 4 bytes length
+14 ACC./Dec. delay of 2nd axis
(4 bytes)
Signed binary format in 4 bytes length
+18
+21
ACC./Dec. delay of 3rd axis
(4 bytes)
Signed binary format in 4 bytes length