6 ADDITION OF THE REQUIRED
CONDITION TO INPUT OR OUTPUT PMC
PARAMETER
The required condition of input or output PMC Parameter on the PMC
data I/O screen has been changed to the same condition as CNC
Parameter.
Input from the data I/O screen
To enter the PMC parameters from the data I/O screen requires the
operation described below. The following methods can be used to enable
the input of the PMC parameters.
(1) If the sequence program is running (RUN state) (Under normal
circumstances, this method should be used when the machine is
operating.)
(a) Place the CNC in the emergency stop state or the EDIT mode.
(b) Set "PWE" on the CNC setting screen to "1".
(c) The protection of the parameters is canceled, making it
possible to enter them.
(d) After entering the PMC parameters, reset "PWE" to its original
state.
(2) If the sequence program is being debugged and can be stopped
(STOP state)
(a) Place the sequence program in the stop state.
(b) The protection of the parameters is canceled, making it
possible to enter them.