4.ADJUSTMENT FANUC AC SPINDLE MOTOR αi series B-65280EN/05
- 214 -
15i 16i 30i
3413 4413 4413
Number of measurement times per frequency
Unit of data : 1 time
Valid data range : 0 to 1000
Standard setting value : 0
Set the number of times a measurement is made per frequency.
When 0 is set, five times are assumed.
Normally, set 0.
15i 16i 30i
3414 4414 4414
Disturbance torque command amplitude
Unit of data : 1% (100% = maximum torque command)
Valid data range : 0 to 50
Standard setting value : 0
Set the amplitude of the disturbance torque command.
When 0 is set, 5% is assumed.
Normally, set 0.
15i 16i 30i
3415 4415 4415
Motor speed command at measurement time
Unit of data : 1min
-1
(Unit of 10min
-1
when bit 2 (SPDUNT) of parameter No. 4006
= 1)
Valid data range : -32768 to +32767
Standard setting value : 0
Set the motor speed command at measurement time.
The speed is clamped at the maximum speed of the motor.
15i 16i 30i
3030 4030 4030
Change rate of motor speed command at measurement
Unit of data : 1min
-1
/sec (Unit of 10min
-1
/sec when bit 2 (SPDUNT) of parameter
No. 4006 = 1)
Valid data range : 0 to +32767
Standard setting value : 0
When a non-zero value is to be set as the motor speed command at
measurement time, set the change rate of the motor speed command to
prevent abrupt acceleration/deceleration.
When the disturbance input function is disabled (DTQFNC = 0), this
parameter is used as the soft start/stop setting time. So, after the
measurements, restore the original value.