
2.EXPLANATION OF OPERATION MODES FANUC BUILT-IN SPINDLE MOTOR Bis series B-65280EN/05
- 530 -
15i 16i 30i
3038 4038 4038
Spindle orientation speed
Unit of data : 1min
-1
Valid data range : 0 to 32767
Standard setting : 0
This parameter sets the orientation speed at the end of the spindle.
When 0 is specified for this parameter, the orientation speed is
determined depending on the position gain and the motor speed limit
ratio for orientation.
15i 16i 30i
3042 4042 4042
Velocity loop proportional gain on orientation (HIGH) CTH1A=0
3043 4043 4043
Velocity loop proportional gain on orientation (LOW) CTH1A=1
Unit of data :
Valid data range : 0 to 32767
Standard setting : 10
This parameter sets the velocity loop proportional gain for spindle
orientation.
When the CTH1A input signal is set to 0, proportional gain for the
HIGH gear is selected. When the CTH1A input signal is set to 1,
proportional gain for the LOW gear is selected.
15i 16i 30i
3050 4050 4050
Velocity loop integral gain on orientation (HIGH) CTH1A=0
3051 4051 4051
Velocity loop integral gain on orientation (LOW) CTH1A=1
Unit of data :
Valid data range : 0 to 32767
Standard setting : 10
This parameter sets the velocity loop integral gain for spindle
orientation.
When the CTH1A input signal is set to 0, integral gain for the HIGH
gear is selected. When the CTH1A input signal is set to 1, integral
gain for the LOW gear is selected.